How ProtecDER works

From Detection to Restoration in Milliseconds

A deep look at the technology, architecture, and real-world operation behind ProtecDER — from the hardware at the feeder edge to the AI engine in the cloud.

The four-step process

Intelligent Protection, End to End

01

Continuous Monitoring

High-frequency voltage and current sampling at every instrumented node.

ProtecDER devices are deployed at key nodes across the distribution feeder — zone substations, distribution transformers, and DER connection points. Each device samples voltage and current waveforms at high frequency, streaming telemetry to the ProtecDER platform in real time. This continuous visibility gives the system a live, high-resolution picture of network state that legacy SCADA systems, with their multi-second polling cycles, simply cannot match.

02

Fault Identification

DER-aware algorithms distinguish genuine faults from normal DER behaviour.

When an anomaly is detected, ProtecDER's AI/ML engine evaluates it against a continuously updated model of expected DER output, load behaviour, and network topology. This is the critical differentiator: legacy overcurrent relays cannot tell the difference between a fault current and the combined export of a street full of solar inverters. ProtecDER can. The result is accurate fault classification with near-zero false-positive trips — protecting both network reliability and DER asset uptime.

03

Rapid Isolation

Affected sections isolated within milliseconds, fault propagation stopped.

Once a genuine fault is confirmed, ProtecDER issues coordinated switching commands to isolate the affected network segment. Critically, DER curtailment commands are issued in parallel — inverters in the affected zone are instructed to cease export before isolation, eliminating the islanding risk that makes DNSPs reluctant to allow high DER penetration in the first place. The entire sequence — detection, classification, curtailment, isolation — completes in milliseconds.

04

Automated Restoration

Network reconfigured automatically to restore supply to unaffected customers.

With the fault isolated, ProtecDER evaluates available network switching paths and coordinates automated reconfiguration to restore supply to all unaffected customers. DER assets outside the fault zone are brought back online in a controlled sequence, respecting protection constraints at every step. The restoration plan is computed in real time against the live network model — not a pre-programmed script — so it adapts to whatever topology exists at the time of the fault.

Real-world scenario

A Fault Event on a High-Solar Feeder

Walk through exactly what happens when a phase-to-earth fault occurs on a feeder with 80% solar penetration — a scenario that defeats legacy protection but is routine for ProtecDER.

T+0 ms

Fault occurs

A phase-to-earth fault develops on a suburban feeder. 47 rooftop solar systems are actively exporting. Legacy relays see ambiguous overcurrent — they cannot determine whether it is a fault or peak solar export.

T+8 ms

ProtecDER detects and classifies

ProtecDER's waveform analysis identifies the fault signature. The AI engine cross-references live DER telemetry and confirms: this is a genuine fault, not a generation event. Classification confidence: 99.3%.

T+12 ms

DER curtailment issued

Curtailment commands are broadcast to all inverters in the affected zone via the DER management interface. Inverters acknowledge and ramp down. Islanding risk is eliminated before any switching occurs.

T+18 ms

Fault section isolated

Switching commands isolate the faulted segment. 94% of customers on the feeder remain on supply. The fault is contained to 6% of the feeder — the minimum physically possible given the fault location.

T+340 ms

Restoration complete

Network reconfiguration restores supply to all customers outside the fault zone. DER assets are brought back online in a controlled sequence. The entire event — from fault to full restoration — takes under 400 milliseconds.

System architecture

Three Layers, One Integrated System

ProtecDER is a hardware-software system. The edge devices provide real-time sensing and actuation; the platform provides intelligence and coordination; the integration layer connects to existing DNSP systems.

Edge layer

ProtecDER Field Devices

  • Installed at zone substations, distribution transformers, and DER connection points
  • High-frequency waveform sampling — voltage, current, power factor
  • Local protection logic for sub-cycle response when cloud latency is unacceptable
  • Secure, low-latency telemetry to the ProtecDER platform
  • Hardened for outdoor substation environments

Intelligence layer

ProtecDER Platform

  • AI/ML engine for DER output forecasting, load modelling, and fault risk scoring
  • Real-time network model updated continuously from field telemetry
  • Protection-aware dispatch engine — every DER dispatch decision evaluated against live protection state
  • Fault classification, curtailment coordination, and restoration planning
  • Audit trail and event logging for regulatory compliance

Integration layer

SCADA, EMS and DERMS Connectors

  • Standard protocol support: IEC 61850, DNP3, Modbus, IEEE 2030.5
  • Bi-directional integration with existing SCADA and EMS platforms
  • DERMS API for coordinated DER dispatch across the feeder portfolio
  • No rip-and-replace — ProtecDER layers on top of existing infrastructure
  • Role-based access control and encrypted communications throughout

Want the Full Technical Briefing?

Our engineering team can walk through the ProtecDER architecture in detail — including protection coordination methodology, Model validation and off-grid testing requirements.